Corrosion testing of metallic coatings – copper accelerated acetic acid salt spray test
Can be used to test the relative resistance to corrosion of metallic coatings, when exposed to a copper accelerated acetic acid salt spray climate at an elevated temperature.
Test specimens are placed in an enclosed chamber and exposed to a continuous indirect spray of acidified (pH 3.1to 3.3) salt water solution, which falls-out on to the specimens at a rate of 1.0 to 2.0ml/80cm²/hour, in a chamber temperature of +50C. This climate is maintained under constant steady state conditions. The test duration is variable.
Chamber volumes of less than 200 Litres are not permitted by this test standard.
This test is also referred to as a CASS test.